Fleck 5600 manual pdf

To manually regenerate the valve, turn the manual regeneration knob clockwise until it reads regen. Manually index the control to the brine fill position and allow the brine tank to fill to the top of. Covers air injection silver, gold, and platinum filter systems. Fleck 5600sxt 48, 000 grain water softener digital sxt. Pentair fleck 5600 manuals and user guides, water filtration. Fleck 5600 sxt digital water softener system installation manual. Pentair fleck 5600 sxt installer manual pdf download. View and download pentair fleck 5600sxt service manual online. An uninterrupted alternating current ac supply is required.

Fleck 5600 12 day skipper wheel setting and operation duration. Fleck manuals water softeners control heads set up and. Backwashing system fleck 5600 series installation instructions. View and download pentair fleck 5600 service manual online. Model 7000 5 valve installation and startup procedures installation instructions 1. Commercial commercial reverse osmosis systems expand. Model 5600se downflow 6 control startup procedures display in normal operation the time of day display alternates with volume remaining display. Be sure the tank is level and on a firm, clean base. Fleck 9000 manual rev unit 6 ap world study guide answers fleck water softener parts for models 5600, 2510, 2750, 2850, 2900, 3900, download 2002 chrysler concorde owners manual. Fill in pertinent information on page 3 for future reference. In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line. Jan 27, 2017 one of the most common questions we get here at aqua science is how to set the time of day and gallons on the fleck 5600 econominder control valve for water softeners. Figure 5 figure 6 next, place the fleck 5600 meter valve onto the top of the tank, being sure.

The filter should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturers recommendations and to meet. View and download fleck 5600 service manual online. Fill in pertinent information on page 2 for future reference. Database contains 1 pentair fleck 5600 manuals available for free online viewing or downloading in pdf. Another problem that can occur with the fleck 5600 econominder metered valve. The softener should be located close to a drain to prevent air. We appreciate your business and look forward to serving you in the future. As treated water is used, the volume remaining display counts down in gallons from a maximum value to zero or. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour. For electronic valves, please refer to the manual regeneration part of the timer operation section. Claimed advantages of the 2510 are that its motors and 1 internals make it more robust, and it has more flexible programming. Scope of the documentation the documentation provides the necessary informatio n for appropriate use of the product. System installation requires information from a number of suppliers not known at the time of manufacture.

Series 5600 ecominder water softeners owners manual. One of the most common questions we get here at aqua science is how to set the time of day and gallons on the fleck 5600 econominder control valve for water softeners. Installation instructions for backwashing systems with fleck 5600 and 5600sxt covers all standard backwashing systems, including asm and adedge arsenic systems, carbon tanks, iron filters, ph tanks, and sediment tanks. Place the softener tank where you want to install the unit. Fleck 5600 econominder service manual pdf download. Model 5600 backwash filter installation and startup procedure 1. Fleck 5600 sxt service manual, the above microtek scanmaker 5800 windows 7 search, the reliable fleck 5600, 2510, 7000, 5600 5600 econominder service manuals pdf heres how you can fix your itunes installation if app. If the valve came with a separate electronic timer service manual, refer to the timer operation section of the electronic timer service manual. Model 7000 9 programming a meter delayed regenerated system 1.

Install the water softener with the inlet, outlet and drain connections made according to manufacturer. Each time the program switch position changes, the valve will advance to the next regeneration step. To set the time of day, push the red button and spin the 24hour gear until the present time of day is visible above the time of day arrow. Once this occurs a regeneration cycle initiates immediately or delayed to the set regeneration time. Mar 15, 2014 fleck 5600 12 day skipper wheel setting and operation duration. A complete faq is at the end of this manual since every installation is different. Turn the manual regeneraton knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins. Turn the manual regeneraton knob slowly in a clockwise. User manuals, guides and specifications for your pentair fleck 5600 water filtration systems. Air injection system fleck 5600 series installation.

It informs the user to ensure efficient execution of the installation, operation or maintenance procedures. Allow the drive motor to move the piston to the first regeneration step and stop. This instructional manual is intended to aid you in the installation and programming of your newly purchased water softener. With proper installation and a little routine maintenance your system will be providing filtered water for many years. Your new system comes with a printed fleck service manual, which along with this startup guide will help guide you in the. Once the water is cleared up a manual backwash should be run. Adapter coupling one complete with clips 1922801 in stock your price.

Pentair fleck 5600 water filtration systems service manual. System installation requires information from a number of. The information, specifications and illustrations in this manual are based on the latest information available at the time of printing. Control valve assembly 6150056se rev a 12 fleck 5600sxt downflow service manual. As far as i can tell it is still fully functioning, i just want to make sure i have it setup to properly regenerate for my household. Installation instructions for air injection systems with fleck 5600 and 5600sxt. The feed water hardness setting only displays when the system is set to operate as a meter immediate or meter delayed system type. Page 7 model 5600se upflow control startup procedures contd. Fleck 5600 from the rear showing the inlet and outlet end.

Fleck manuals water softeners control heads set up. The way to tell if this part needs replacement is to remove the meter dome, turn the cable attached by hand and observe the small white gears inside. Fleck 5600 water filtration systems pdf manual download. Push the red time set button in and rotate the 24 hour time gear until the current time arrow lines. Air injection system fleck 5600 series installation instructions. Need a bit of help setting up older fleck econominder 5600. Installer manual fleck 5600 sxt maintenance maintenance mandatory cleaning and maintenance shall take place at regular intervals in order to guarantee the proper functioning of the complete system, and be documented in the maintenance chapter in the user guide document. Startup instructions the water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturers recommendations, and to meet applicable plumbing codes. This manual is intended as a guide for service of the valve only. Electrical facilities an uninterrupted alternating current ac supply is required.

Turn the manual regeneration knob slowly in a clockwise. Claims for the 5600 are that its simpler, cheaper and longterm reliable, and its not likely that id need the extra cycleadjustment capabilities. It is a good idea to allow the system to run through a manual cycle. Fleck 2510 service manual pdf fleck 5600 brochure pdf fleck 5600 owners manual pdf model 5600 service manual. Manual for fleck model 5600 and 5600 econominder valve in stock your price. Manually index the softener control into the in service position and let water flow into the resin tank. Fleck 5600sxt water softener instructions overview thank you for your water softener purchase from aquatell. Model 7000 service manual discount water softeners. To manually regenerate the valve, turn the manual regeneration knob clockwise until it reads. View online service manual for pentair fleck 5600 water filtration systems or simply click download button to examine the pentair fleck 5600 guidelines offline on your desktop or laptop computer. If necessary, set salt in accordance with the setting instruction sheet. Install the water softener with the inlet, outlet and drain connections made according to manufacturers recommendations and to meet applicable plumbing codes.

862 1179 281 414 607 821 1116 1293 956 1073 957 873 1335 223 667 1441 373 308 726 1219 855 533 245 525 1422 16 623 1539 665 411 1345 1222 711 495 1391 290 1426 1474